A COMPARATIVE STUDY OF SO2 & SO3 REMOVAL IN DRY INJECTION FGD PROCESSES
Item
-
Title
-
A COMPARATIVE STUDY OF SO2 & SO3 REMOVAL IN DRY INJECTION FGD PROCESSES
-
Project ID
-
05-1/ER8
-
Investigator
-
Abbasian
-
Institution
-
Illinois Institute of Technology
-
Abstract
-
During the pulverized coal combustion process sulfur in coal is released mainly in the form of sulfur dioxide (SO2) in the flue gas. However, a small fraction of the SO2 (i.e., 0.5% to 1.5%) is further oxidized by the excess oxygen in the flue gas to form SO3 that combines with the moisture in the flue gas to form a mist of sulfuric acid, also known as the "blue plume," which is the biggest impediment to Illinois basin coals displacing appalachian coals in newly scrubbed units in the southeast. In some instances, utilities are experiencing a blue plume following the retrofit of selective catalytic reduction (SCR) for the control of emissions of nitrogen oxide (NOX) on units equipped with FGD's. In addition to environmental problems and concerns, sulfuric acid in the flue gas can cause various power plant operating and maintenance problems. Condensation of sulfuric acid has a significant detrimental effect on downstream equipment, including fouling and corrosion of heat transfer surfaces in the air heater. Condensation of sulfuric acid in the flue gas can be controlled by raising the flue gas temperature. However, higher air heater temperature will result in lower overall plant efficiency. In power plants that are equipped with Selective Catalytic Reduction (SCR) systems for NOX control, sulfuric acid can cause catalyst deactivation. Finally, sulfuric acid reacts with ammonia (injected for NOX control in SCR) to form ammonium sulfate and ammonium bisulfate. The latter is a sticky solid substance that can combine with, and contaminate fly ash, and foul the air heater. Sulfuric acid in the stack gas also contributes significantly to PM2.5 releases, which is expected to be regulated by year 2010. Unfortunately, despite all the problems associated with the presence of SO3 in the flue gas, this area of research has not received much attention. The results of previous studies suggest that, depending on the properties and amount of sorbent used and injection location 20%-90% of SO3 can be removed from the flue gas by calcium-based sorbents. However, a systematic study of the comparative reactivities of different commercially available Ca/Mg-based sorbents (i.e., limestone and dolomite) toward SO2 & SO3 is needed to determine their effectiveness for removal of SO3 in dry injection FGD processes designed for SO2 removal. The goal of this program is to generate the necessary information to aid the utilities in the selection of suitable alkaline sorbents as well as sorbents injection strategies for the removal of sulfuric acid from the flue gas of coal-fired utility boilers. The objective of this exploratory research project was to generate experimental data on the comparative reactivities of different commercially available Ca/Mg-based sorbents (i.e., limestone and dolomite) toward SO2 & SO3 to determine their effectiveness for removal of SO3 in dry injection FGD processes designed for SO2 removal. To achieve this objective, samples of a high purity dolomite as well as a high purity limestone were procured for testing in this project. The dolomite sample was obtained from Thornton Quarry located in Illinois, while the limestone sample was obtained from Southern Illinois Power Cooperative Inc., (SIPC). The sorbents were crushed, sieved, and divided in different size ranges. The -50 / +40 fraction (i.e., dp = 300-425 µm) was selected for testing in this project. A total of fifty four (54) sulfation tests involving dolomite/limestone and SO2/SO3 were conducted in the thermogravimetric Analyzer (TGA) reactor. These tests were conducted in the temperature range of 650° to 850°C with simulated flue gas mixtures containing 10% steam, 14% CO2, 3% O2 and nitrogen. The SO2 content of the flue gas ranged from 0 to 2500 ppmv and the SO3 content ranged from 0 to 500 ppmv. The results of the TGA tests with SO2 indicate the rate of sulfation reaction involving dolomite and SO2 is first order with respect to SO2 concentration. The results also indicate that the reactivity of dolomite toward SO2 decreases with increasing temperature above 650°C, which may be attributed to partial sintering of the sorbent at elevated temperatures. The results obtained with the limestone indicate that the rate of sulfation reaction involving limestone and SO2 also appears to be first order with respect to SO2 concentration and that the reactivity of limestone toward SO2 increases with increasing temperature. However the apparent activation energy is very low, suggesting the possibility of partial sintering. Furthermore, the results indicate that although the reactivity of dolomite is higher than that of the limestone, because of the higher calcium content of the limestone, the sulfur loading of the limestone is higher than that of the dolomite. In the TGA test involving SO3, (where sulfuric acid was used as the precursor), because of the high dew point of the sulfuric acid mixture and temperature limitation of the inert PFA® feed line, condensation was as a major experimental problem. The results indicate that because of the condensation and the low concentration of SO3 used in the TGA experiments, the TGA reactor may not have been operating as a "differential" reactor, where the concentration of the reactive gaseous component in the reactor exit line is very close to the feed concentration. This leads to the conclusion that a significant level of uncertainty is associated with the actual concentration of SO3 during these runs. Therefore, it should be concluded that the reactivities of the sorbents toward SO3 obtained in this project are believed to be significantly lower than the "actual" values.
-
Year Funded
-
2005
-
Start Date
-
9/1/2005
-
End Date
-
8/31/2006