Abstract
The objective of this exploratory research project was to generate experimental data on
the comparative reactivities of different commercially available Ca/Mg-based sorbents
(i.e., limestone and dolomite) toward SO2 & SO3 to determine their effectiveness for
removal of SO3 in dry injection FGD processes designed for SO2 removal.
To achieve this objective, samples of a high purity dolomite as well as a high purity
limestone were procured for testing in this project. The sorbents were crushed and
sieved, and the -50 / +40 mesh fraction (i.e., dp = 300-425 μm) was selected for testing in
this project.
A total of fifty four (54) sulfation tests involving dolomite/limestone and SO2/SO3 were
conducted in the thermogravimetric Analyzer (TGA) reactor. The results of the TGA
tests with SO2 indicate the rate of sulfation reaction involving dolomite and SO2 is first
order with respect to SO2 concentration and that the reactivity of dolomite toward SO2
decreases with increasing temperature above 650°C, which may be attributed to partial
sintering of the sorbent at elevated temperatures. The results also indicate that the rate of
sulfation reaction involving limestone and SO2 also appears to be first order with respect
to SO2 concentration with the reactivity increasing with increasing temperature.
However the apparent activation energy is very low, suggesting the possibility of partial
sintering. Furthermore, the results indicate that although the reactivity of the dolomite is
higher than that of the limestone, because of the higher calcium content of the limestone,
the sulfur loading of the limestone is higher than that of the dolomite at all conditions
tested.
In the TGA test involving SO3, (where sulfuric acid was used as the precursor), because
of the high dew point of the sulfuric acid mixture and temperature limitation of the inert
PFA® feed line, condensation was a major experimental problem. The results indicate
that because of the condensation and the low concentration of SO3 used in the
experiment, a significant level of uncertainty is associated with the actual concentration
of SO3 during these runs. Therefore, it should be concluded that the reactivities of the
sorbents toward SO3 determined in this project are significantly lower than the “actual”
values.